Intel RS2BL080 Benutzerhandbuch

Seite von 42
Appendix A: Event Messages and Error Codes 
Intel® RAID Controller RS2BL080 Technical Product Specification 
 
 
Revision 1.0
 
 
Intel order number E64388-001 
36 
Number  
Type  
Description  
63 
Information 
Consistency Check found inconsistent parity on %s at stripe %lx  
64 
Warning 
Consistency Check inconsistency logging disabled on %s (too many inconsistencies)  
65 
Progress 
Consistency Check progress on %s is %s  
66 
Information 
Consistency Check started on %s  
67 
Information 
Initialization aborted on %s  
68 
Critical 
Initialization failed on %s  
69 
Progress 
Initialization progress on %s is %s  
70 Information 
Fast 
initialization started on %s  
71 
Information 
Full initialization started on %s  
72 
Information 
Initialization complete on %s  
73 
Information 
%s Properties updated to %s (from %s)  
74 
Information 
Reconstruction complete on %s  
75 
Fatal 
Reconstruction of %s stopped due to unrecoverable errors  
76 
Fatal 
Reconstruct detected uncorrectable multiple medium errors (%s at %lx on %s at %lx)  
77 
Progress 
Reconstruction progress on %s is %s  
78 
Information 
Reconstruction resumed on %s  
79 
Fatal 
Reconstruction resume of %s failed due to configuration mismatch  
80 
Information 
Reconstruction started on %s  
81 
Information 
State change on %s from %s to %s  
82 
Information 
Clear aborted on %s  
83 
Critical 
Clear failed on %s (Error %02x)  
84 
Progress 
Clear progress on %s is %s  
85 
Information 
Clear started on %s  
86 
Information 
Clear completed on %s  
87 
Warning 
Error on %s (Error %02x)  
88 
Information 
Format completed on %s  
89 
Information 
Format started on %s  
90 
Warning 
Hot Spare SMART polling failed on %s (Error %02x)  
91 
Information 
Inserted: %s  
92 
Warning 
%s is not supported  
93 
Information 
Patrol Read corrected medium error on %s at %lx  
94 
Progress 
Patrol Read progress on %s is %s  
95 
Fatal 
Patrol Read found an uncorrectable medium error on %s at %lx  
96 
Warning 
Predictive failure: %s  
97 
Fatal 
Puncturing bad block on %s at %lx  
98 
Information 
Rebuild aborted by user on %s  
99 
Information 
Rebuild completed on %s  
100 
Information 
Rebuild completed on %s  
101 
Critical 
Rebuild failed on %s due to source drive error  
102 
Critical 
Rebuild failed on %s due to target drive error  
103 
Progress 
Rebuild progress on %s is %s  
104 
Information 
Rebuild resumed on %s  
105 
Information 
Rebuild started on %s  
106 
Information 
Rebuild automatically started on %s