Enterasys 2200 Betriebsanweisung

Seite von 330
Example 6, Securing Sensitive Information According to Subnet
VLAN Operation and Network Applications
12-43
2. The VLAN Classification Configuration screen is used to configure the switch to detect and 
classify the incoming RIP broadcast frames on Port 25 to the Null VLAN. Since the Null VLAN 
is not assigned to any port, the frame is dropped (not transmitted out any port). The VLAN 
Classification Configuration screen is set as follows:
VID: 99
Classification: Dest UDP Port 
IP UDP Port: 520
Port 520 is a well known port number used by RIP.
12.17 EXAMPLE 6, SECURING SENSITIVE INFORMATION ACCORDING 
TO SUBNET
The ABC Company wants to confine the sensitive information being transmitted by their Finance 
Department to its users only.
In this example, illustrated in 
, the users in the Finance Department are members of 
the Finance VLAN and are also on subnet 28 as shown in bold type. 
Figure 12-24
Example 6, Securing Traffic to One Subnet
30691_74
Port 25
S1
Finance
Department
User Subnet
Class B  Address:
123.123.28.1
123.123.28.2
123.123.28.3
123.123.28.4
123.123.28.5
Engineering
Department
User Subnet
Class B  Address:
123.123.50.1
123.123.50.2
123.123.50.3
123.123.50.4
123.123.50.5
Finance
Server
123.123.28.25
Other Users
123.123.xx.xx