Troubleshooting
CyberSWITCH 100 Advanced User Information 49
LOGIN PASSWORD IS INVALID
You have been prompted for the login password and received this message.
Re-enter the correct password and press ENTER. Remember that the password is 
case-sensitive. Check that you are entering admin in lowercase.
If you have forgotten the password, you must reset the login password. You must have the Console 
Cable installed, and use the Command Line Interface to do this procedure. 
Perform the following procedure:
1.
Move Switch 1 and 2 DOWN.
2.
Type “login newpasswd”. Password checking is overridden. 
3.
Move Switch 1 and 2 UP.
4.
Complete any configuration update that caused the prompt for login.
5.
Change your login password to a new password.
6.
Store the configuration and reboot the router.
USER CANNOT COMMUNICATE WITH REMOTE NETWORK STATION
Check that the ISDN line SPIDs and DNs (if required) are valid, the telephone switch settings 
are correct and the line can be activated.
Verify that the ISDN phone numbers are correct for the remote router.
If you are not using the supplied ISDN cable, check that the cables are pinned correctly.
Start the Monitor and check the status of the ISDN B channels.
Verify that PAP/CHAP passwords are correct. Ensure that the remote router operates at the 
same minimum level of security that you have set in the target router.
Bridging 
Check that the Bridging Default Destination is set.
Check that bridging to/from the remote router is set on. 
NOTE
If you have not reset Switch 1 and 2 UP and have rebooted, you will place the router in 
maintenance mode. Set Switch 1 and 2 UP and turn the power OFF and then ON.