Enterasys csx400 Merkblatt

Seite von 2
 
CSX500 Setup Guide
PN 9032534-03
Page 2 of 2
 
QuickSet Utility: Configuring the CSX500
 
Refer to the QuickSet QuickStart Guide located inside the QuickSet CD jewel case and follow the QuickSet 
procedure to configure the CSX500. 
 
Full or Half Duplex Configuration on the LAN Port
 
If the version of QuickSet that you are running does not have the button in QuickSet to change the duplex setting, 
use the following procedure.
The LAN port on the CSX500 is set to connect using half duplex by default. If a LAN connection is needed for full 
duplex, the CSX500 must be configured using Network Tools. Refer to the Cabletron Systems 
 
Local Management 
User’s Guide for CSX200, CSX400, CSX400-DC, HSIM-W6, and HSIM-W84
 
 to configure the CSX500 using 
Network Tools. Use the following procedure to set the port to full duplex:
1. Use this OID to change the LAN port from the default of half duplex to full duplex:
ctIf Duplex: 1.3.6.1.4.1.52.4.3.3.2.1.1.5
2. Set the OID string to 3 (full) in order to set the port to full duplex. Set the OID string to 2 (standard) for the port 
to be set to half duplex speed.
 
GETTING HELP
 
For additional support, contact the Cabletron Systems Global Call Center:
 
 
 Copyright 1998 by Cabletron Systems, Inc., P.O. Box 5005, Rochester, NH 03866-5005
All Rights Reserved. Printed in the United States of America.
 
Cabletron Systems
 
 and 
 
QuickSet 
 
are registered trademarks, and 
 
SmartSwitch 
 
is a trademark of Cabletron Systems, Inc.
NOTE
 
Refer to the 
 
Read Me First!
 
 instruction sheet enclosed with the device to ensure that your PC is ready for 
the QuickSet configuration using the QuickSet CD.
NOTE
 
If the LAN connection required is half duplex, and the port is configured for full duplex, the connection 
may appear to work, but problems can occur on the network. To prevent data corruption, change the 
connection to the appropriate duplex setting.
If a bootp download is required at full duplex speed, an internal DIP switch must be accessed and 
switch 1 of the DIP switch set for the bootp to be successful. Refer to the Cabletron Systems
 
 
 
Local 
Management User’s Guide for CSX200, CSX400, CSX400-DC, HSIM-W6, and HSIM-W84
 
 
 
for 
more information on the bootp download procedure.
 
World Wide Web
http://www.cabletron.com/ 
Phone
(603) 332-9400
Internet mail
support@cabletron.com
FTP
ftp://ftp.cabletron.com/
Login 
 
anonymous
 
Password 
 
your email address
 
To send comments or suggestions concerning this document, contact the 
Cabletron Systems Technical Writing Department via the following 
email address:
 
TechWriting@cabletron.com
 
Make sure to include the document Part Number in the email message.