Connecting the CSX400-DC to the Power Source
CyberSWITCH CSX400 and CSX400-DC Installation Guide
4-15
Connecting the CSX400-DC to the Power Source
Th CSX400-DC requires either a 48 Vdc or 60 Vdc (48/60 Vdc), 3.5 A (maximum), external power 
source supplied by three 18 AWG (American Wire Gauge) copper wires. These wires must be 
terminated to the dc input power strip shown in 
 with either ring or spade terminals. 
The dc power supply in the CSX400-DC has its own on/off switch and is rated at 100 watts. To 
connect the CSX400-DC to a 48/60 Vdc power source, face the back panel, then refer to 
ONLY QUALIFIED PERSONEL SHOULD PERFORM THESE INSTALLATION 
PROCEDURES.
TO REDUCE THE RISK OF ELECTRIC SHOCK OR ENERGY HAZARDS:
CONNECT TO A RELIABLY GROUNDED 48/60 VDC SELV SOURCE.
ENSURE THE BRANCH CIRCUIT OVERCURRENT PROTECTION IS 
RATED AT A MIMINUM OF 10 A.
USE 18 AWG SOLID COPPER CONDUCTORS ONLY.
ENSURE THAT A READILY ACCESSIBLE DISCONNECT DEVICE THAT IS 
SUITABLY APPROVED AND RATED, IS INCORPORATED IN THE FIELD 
WIRING.
TO BE INSTALLED IN A RESTRICTED ACCESS AREA IN ACCORDANCE WITH 
THE NEC OR THE AUTHORITY HAVING JURISDICTION.