WPIM-SYNC Installed in CSX200
The port is operating normally. If it is not, and this LED is OFF the port may be disabled or RTS 
may be inactive.
Use QuickSET or Local Management to make sure that the WAN interface on the Local device 
is configured correctly.
WPIM-HDSL Installed in CSX200
The port is disabled or has been placed into Loopback Test mode.
Use QuickSET or Local Management to make sure that the WAN interface on the Local device 
is configured correctly.
Use QuickSET or Local Management to make sure that the WAN interface on the Remote 
device is configured correctly.
Status 1 (STS1) LED is RED
WPIM-T1, WPIM-E1, or WPIM-DI Installed in CSX200 is in RED Alarm Mode
A RED alarm indicates that the WAN connection is not receiving proper framing or has lost 
framing.
Verify the use of proper cabling on the WAN connection.
Check Frame Type selection on the WAN Physical Configuration and line coding.
Possible bad cabling between Telco and CSX200.