IP (S
UB
) N
ETWORK
 N
UMBER
If the CyberSWITCH uses an IP RLAN interface to connect to a remote bridge, you must provide 
this information. 
This address associates the bridge with the IP network to which it connects. Enter this address 
using dotted decimal notation. This parameter applies to the network-portion of the IP address 
only. Note that if you change the IP address under the IP information menu selection, this parameter 
will reflect that change.
E
NABLE
/D
ISABLE
 B
RIDGING
You may enable or disable bridging on a per device basis. You must enable bridging for remote 
LAN devices, which indicates that the remote device is a bridge and not a router.
M
AKE
 C
ALLS
 
FOR
 B
RIDGE
 
DATA
You must enable this element to allow bridge dial out to function. You must also complete the 
following configuration:
Enable bridging at the system level and at the per-device level.
Either add the device to the CyberSWITCH’s Known Connect List, or configure a bridge con-
nection filter. For information regarding the Known Connect List, 
. For infor-
mation regarding bridge filters, 
.
Note: This feature is not yet supported for IPX Remote LANs.
IPX R
EMOTE
 LAN N
ETWORK
 N
UMBER
If the CyberSWITCH uses an IPX RLAN interface to connect to a remote bridge, you may choose to 
change this information. 
This parameter associates the bridge with the IPX network to which it connects. Enter the IPX 
external network number of the remote LAN, or accept the default value of none
If this parameter remains none, the CyberSWITCH will assume the network number is that of the 
first configured IPX Remote LAN interface. This is convenient in applications in which remote 
LANs consist only of clients (thus no explicit external network address), all of which are on the 
same external virtual LAN.
If you choose to change this parameter, you must specify the IPX external network number used 
on the remote LAN in question. This value must be the same as the value configured for the 
corresponding IPX Remote LAN interface. 
IPX S
POOFING
 O
PTIONS
Note:  This feature is not yet supported for IPX Remote LANs. Do not attempt to configure.
A
PPLE
T
ALK
 N
ETWORK
 N
UMBER
If the CyberSWITCH uses an AppleTalk WAN (Remote LAN) port to connect to a remote bridge, 
you may choose to change this information. 
This parameter associates the bridge with the AppleTalk network to which it connects. Enter the 
AppleTalk network number/range (which corresponds to a configured AppleTalk Remote LAN 
port), or accept the default value of none. If this parameter remains none, the CyberSWITCH will 
assume an association with the first configured AppleTalk Remote LAN port.