Enterasys csx150 Betriebsanweisung

Seite von 620
USER’S GUIDE
296      CyberSWITCH
3.
Follow the onscreen instructions to keep the feature enabled.
4.
Enter the sample rate in seconds.
5.
Enter the overload trigger number.
6.
Enter the overload window size.
7.
Enter the overload percentage utilization.
8.
Enter the underload trigger number.
9.
Enter the underload window size.
10. Enter the idle trigger number.
11. Enter the idle window size.
12. Enter the idle percentage utilization.
13. Press "Y" to accept the configuration changes you have made.
U
SING
 M
ANAGE
 M
ODE
 C
OMMANDS
thruput
Displays the current throughput monitor configuration data.
thruput change
Allows the current throughput monitor configuration data to be changed. Refer to the 
CFGEDIT section for specific parameters.
T
HROUGHPUT
 M
ONITOR
 C
ONFIGURATION
 E
LEMENTS
S
AMPLE
 R
ATE
A Sample Rate identifies the number of seconds for each sample period. The default setting for the 
sample rate is 5 seconds. During this period, the system keeps track of the total number of bytes 
that is transferred in both directions between two systems. The utilization percentage is determined 
by comparing this total with the realistic maximum for the current aggregate amount of 
bandwidth.
O
VERLOAD
 T
RIGGER
 N
UMBER
The number of samples within the window that must exceed the specified utilization for the 
OVERLOAD condition to occur.
O
VERLOAD
 W
INDOW
 S
IZE
The number of sample periods (up to 32) that you should use as the sliding window.
O
VERLOAD
 P
ERCENT
 U
TILIZATION
The percentage of the available bandwidth that the traffic samples must exceed for an overload 
condition to occur.