Enterasys csx150 Betriebsanweisung

Seite von 620
Small Office Remote Access Switch      311
C
ONFIGURING
 C
ALL
 C
ONTROL
Semipermanent Connections
Call Restrictions
You may wish to disable call restrictions when using semipermanent connections. Call restrictions 
are mainly intended for use in areas where “per minute” ISDN tariffs are in place. Typically, this 
in not the case if semipermanent connections are in use.
If you decide not to disable Call Restrictions, we recommend that you make the following Call 
Restriction parameter alterations:
Change the maximum call duration to warn only.
Add 1,440 minutes to the Call Minutes per Day for every call in a configured semipermanent 
connection.
Add 43,200 minutes to Call Minutes per Month for every call in a configured semipermanent 
connection.
Allow calls for all hours in the day.
Refer to the instructions for changing th
Throughput Monitor
The semipermanent connection feature, along with the throughput monitor, interact to prevent the 
CyberSWITCH from dropping calls which are part of the semipermanent connection. 
However, specific considerations apply to the use of the Throughput Monitor. Consider these two 
situations:
1.
To connect two systems together with semipermanent connections:
For each system, configure a semipermanent connection to the other, and enable Throughput 
Monitoring on both. 
However, you may occasionally see a “glare” condition (i.e., both machines attempting to 
reestablish the connection after a network or power outage). This “glare” condition will not 
occur if the semipermanent connection utilizes the entire bandwidth available at either system 
site. Normal throughput monitoring will drop the extra call if traffic allows. 
If this glare condition is unacceptable, you may either:
Delete all Dial-Out phone numbers (through CFGEDIT, Device List entries) for one of the 
sites. The other site (that still has Dial-Out configured) will then create the semipermanent 
connection. 
Treat one system as a device which does not support semipermanent connections. (See 
item 2, which follows).
2.
To connect an system to a machine that does not support semipermanent connections, disable 
Throughput Monitoring at the remote device.
If neither of these options are used, the remote device may periodically drop calls which are 
members of a semipermanent connection. The semipermanent connection feature will stop making 
calls if the number of connections dropped reaches the maximum within configured time limit. If 
this happens, you will need to use the 