Enterasys csx150 Betriebsanweisung

Seite von 620
Small Office Remote Access Switch      319
C
ONFIGURING
 O
THER
 A
DVANCED
 O
PTIONS
Default Line Protocol
D
EFAULT
 L
INE
 P
ROTOCOL
The default values for this feature are adequate for most situations. Instructions are included for 
the rare instance that you need to alter the configuration.
Note:
This feature does not apply to analog connections (including digital modem).
C
ONFIGURING
 D
EFAULT
 L
INE
 P
ROTOCOL
 
U
SING
 CFGEDIT
1.
Select Default Line Protocol from the Options menu.
2.
Change the action on the frame timeout.
3.
Change the frame timeout value.
U
SING
 M
ANAGE
 M
ODE
lineprot
 Displays the current default line protocol configuration.
lineprot change
Allows you to change the default line protocol configuration. For the configuration steps, refer 
to the previous CFGEDIT section.
D
EFAULT
 L
INE
 P
ROTOCOL
 C
ONFIGURATION
 E
LEMENTS
A
CTION
 
ON
 F
RAME
 T
IMEOUT
The action to be taken if no frame is received before the configured frame timeout value has 
expired. The default value is to disconnect the call. The complete list of choices is as follows:
Disconnect
Use HDLC Bridge Protocol
Use IP Host Protocol (RFC 1294)
Use PPP Protocol
F
RAME
 T
IMEOUT
 V
ALUE
The time limit to wait to receive a packet. The default frame timeout value is 30 seconds. The 
possible range is from 5 to 60 seconds.
D
EFAULT
 L
INE
 P
ROTOCOL
 B
ACKGROUND
 I
NFORMATION
When a connection occurs, the system waits for a packet to arrive, and from that packet, it 
determines the protocol type. After a default frame timeout value of 30 seconds, if no packet is 
received, the default action on frame timeout is to disconnect the call. 
It is possible to change the timeout value for waiting for responses. You may also change the action 
on frame timeout. Instead of disconnecting after the frame timeout value has been reached, you can 
select a default protocol for the system to use.