Enterasys csx150 Betriebsanweisung

Seite von 620
Small Office Remote Access Switch      371
P
ROBLEM
 D
IAGNOSIS
Remote Device Connectivity
R
EMOTE
 D
EVICE
 C
ONNECTIVITY
Problem:
A remote device is not able to connect to the CyberSWITCH.
Set-up:
The system software should be up and running. (At the administration console: if you are in the 
Connection Monitor window, exit to the “[
System Name
] >” prompt.)
1.
Enable the call trace messages with the 
trace on
 console command.
2.
Erase the current system messages using the 
er
 console command.
3.
In a controlled manner, initiate an ISDN connection from the remote device. 
Action:
1.
After a connection has been initiated, view the system messages (display system messages by 
issuing the 
dr
 console command). Look for the following call request messages among the 
system messages:
In - INCOMING CALL Call Id=<call Id> Slot =<slot #> Port=<port #> Chans=<bearer 
channel map> Ces=<comm endpoint suffix> Rate=<data rate>
Out - CONNECT Call Id=<call Id> Slot=<slot #> Port=<port #> Chans=<bearer 
channel map> Ces=<communication endpoint suffix> ConnId=<connect Id>
In - CONNECT Call Id=<call Id> Slot=<slot#> Port=<port #> Chans=<bearer channel 
map> Ces=<communication endpoint suffix> ConnId=<connect Id>
If the system reports these messages, then continue with the next step.
If the system does not report these messages, the remote device is not correctly connecting to 
the system. Check and verify the configuration of the remote device.
2.
If the system displays the following message among the system messages (display system 
messages by issuing the 
dr
 console command),
Security Rejection-Invalid Calling Line Id - <#>
the network is indicating a calling line identifier that is not configured for any valid device in 
the system Device list. The number “# ” indicates the actual number presented by the network.
3.
For Remote Bridge Devices:
If the system displays the following messages among the system messages, 
Security Rejection - Caller did not negotiate security
Security Rejection - No Bridge Address given by caller
Security Rejection - Unknown Calling Bridge
Security Rejection - No Password given by caller
Security Rejection - Invalid Password given
Security Rejection - HDLC not supported by the caller
review the system configuration for the Device List. You can also refer to th
 
chapter for the message meanings and the appropriate actions to be taken.
4.
For IP Host Devices:
If the system displays the following messages among the system messages: 
IP Call Dropped: ID_RSP was not received from remote
IP Call Dropped: XID was not received from remote