USER’S GUIDE
384      CyberSWITCH
6.
Verify device configuration on remote bridge. Bridge devices should be configured to make 
calls over the interface defined to go to the router. 
Problem:
The router does not forward typical data (RIP, SAP, Type 20 packets) to the remote bridge.
Action:
1.
Make sure a call is up. Remember, the router cannot forward data if there is no previous 
connection (i.e., router currently does not support dial-out). 
2.
Check IPX device information on the router side. Refer t
 for details.
Problem:
Data is not received by a remote client (or server) on a Remote LAN network, but the call does come 
up between the router and the remote bridge.
Action:
1.
Double check and resolve any configuration/connection problems for the client (or server) to 
the bridge on the Remote LAN. (Basically, eliminate the possibility of any LAN configuration 
problems which are unrelated to the Remote LAN interface). 
2.
If you determine the problem is related to the Remote LAN, verify the IPX Network Number 
for the remote bridge in the router’s configuration (under bridging properties). Refer to 
 for details.
IPX R
OUTING
 
OVER
 
THE
 WAN C
ONNECTION
Problem:
The remote NetWare server does not appear in the NetWare client’s network neighborhood.
Action:
1.
Verify that the routing entry for the remote NetWare’s internal network exists by entering the 
following command.
ipx route
If the route entry does not exist, add a static route to it using the 
ipxroute add
 command 
(Manage Mode) because no route information (RIP packets) are exchanged over the WAN 
connections.
2.
Verify that the proper service entries of the remote NetWare server exist by entering the 
following console command:
ipx service
If the proper service entries do not exist, add static services using the 
ipxservice
 
command 
(Manage Mode) because no service information (SAP packets) are exchanged over the WAN 
connections.
3.
Verify that the CyberSWITCH has SAP processing enabled for the LAN interface by using the 
ixpnetif
 command (Manage Mode). If the SAP processing is not enabled, change the 
configuration for the network interface.