Small Office Remote Access Switch      391
P
ROBLEM
 D
IAGNOSIS
SNMP
Problem:
The CyberSWITCH does not generate SNMP Trap PDUs.
Action:
1.
Enter the 
snmp stats 
command at the administrative console. If an “SNMP is not enabled” 
message appears, you must first enable the SNMP Agent (using CFGEDIT).
2.
If the SNMP statistics are displayed, check the value of the “
snmpOutTraps
” statistic. If this 
counter is zero, the SNMP agent has not generated any Traps. Check your configuration setup 
and ensure that at least one SNMP Trap Receiver is configured. If the value of the 
snmpOutTraps
” statistic is non-zero, the SNMP agent is generating Trap PDUs. If a given 
Network Management Station is not receiving Traps as expected, check your configuration 
setup and ensure that the IP address and the Community Name of the Network Management 
Station that is not receiving Traps is configured properly.
3.
Enter 
dr
 at the administrative console to display the current system messages. If one of the 
following messages appears, the SNMP agent does not have enough memory to generate all of 
the Trap PDUs that need to be generated. If the “snmpOutTraps” counter is not increasing 
while these reports are being logged, there is an unexpected condition present within the 
CyberSWITCH System software.
 
Contact Customer Support.
[SNMP] Unable to obtain an SNMP Trap queue header
[SNMP] Unable to obtain an SNMP Trap queue entry buffer
Problem:
The following message is continuously reported in the system log (enter the 
dr
 console command 
to display the system log):
[SNMP] Authentication failure, unknown community name
Action:
The Community Name specified in the request PDUs is not recognized by the SNMP Agent. To 
correct this problem, use CFGEDIT to add the desired community name or change the 
configuration of your Network Management Station so that it uses a Community Name that is 
known to the CyberSWITCH.
Problem:
The following message is continuously reported in the system log (display the system log by 
issuing the 
dr
 console command):
[SNMP] Authentication failure, improper access rights
Action:
The Community Name specified in the request PDUs does not have the proper access rights to 
perform the desired request. Use CFGEDIT to change the MIB access level of the indicated 
Community Name to the desired access level or change the configuration of your Network 
Management Station so that it uses a Community Name that has the desired MIB access level.