Chapter 9: Configuring Unicast Routing on the SSR
120
CoreWatch User’s Guide
Setting Global Parameters for Unicast Routing
Configuration Expert lets you configure global unicast routing parameters for RIP. To 
configure these global parameters:
1.
Start Configuration Expert if you have not already done so. 
2.
Open the configuration file you want to modify and then double-click that file’s 
Routing Configuration object.
3.
Double-click the IP Routing Configuration object.
4.
Double-click the IP Unicast Routing object. Then click the Unicast Global Parameters 
object.
An IP Unicast Global Parameters dialog box similar to the following appears:
Figure 63. IP Unicast Global Parameters Dialog Box
5.
Enter a number from 1 to 65534 to specify the SSR’s autonomous system number in 
the Assigned Autonomous System # box. The default is 1.
6.
In the Autonomous Loop Count box, enter the number of times the Autonomous 
System may appear in the Autonomous System path. The default is 1.
This entry is only required if the router is going to run protocols that support 
autonomous system paths, such as the Border Gateway Protocol (BGP).
7.
Enter the router ID that is for OSPF’s use.
The most preferred address for the router ID is any IP address other than 127.0.0.1 on 
the loopback interface. If there are no secondary addresses on the loopback interface,