INSTALLATION REQUIREMENTS/SPECIFICATIONS
2-6
 
2.3.5
Transceiver Requirements
 
When you connect an external network segment, via a transceiver, to the 
MRXI with an EPIM-A, the following requirements must be met:
The transceiver or Ethernet Device to which the module will be 
connected must meet IEEE 802.3 standards, and/or Ethernet Version 
1.0 or Version 2.0 standards.
The Signal Quality Error (SQE) test function on the transceiver must 
be disabled if you connect it to a repeater or to an Ethernet Version 1.0 
device. In addition, some Version 2.0 equipment does not support the 
SQE test. Devices that do not support SQE test interpret the SQE test 
pulse as a collision.
 
2.3.6
AUI Cable Requirements
 
When you connect an external network segment to the MRXI with an 
EPIM-A or EPIM-X, the AUI cable must meet the following 
requirements:
 
AUI Cable
 
 - The AUI cable
 
 
 
connecting the module to a device must 
be IEEE 802.3 type cable.
 
Length - The AUI Cable must not exceed 50 meters in length. If 28 
AWG thin office drop AUI cable is used, then the maximum cable 
length is limited to 50 feet (15.24 meters).
Grounding - The connector shell of the EPIM-A and the EPIM-X are 
connected to ground.