Installing the FN100
Fast Network 100 User Guide
Page 2-3
2.3.2 Rack-Mounting the FN100
The table below describes some general considerations you should be 
aware of before mounting the FN100 in a rack assembly.
The FN100 can be rack-mounted in a standard 19-inch equipment cabinet 
(EIA RS310C). To mount the FN100 in a rack assembly, apply the 
following steps:
1. Attach the rack-mount brackets to either side of the FN100
chassis.
2. Place the FN100 chassis in the cabinet.
Table 2-1
General Considerations for Mounting the FN100
Consideration
Discussion
Temperature
Since the temperature within a rack assembly may 
be higher than the ambient room temperature, 
make sure the rack-environment temperature is 
within the Operating Temperature range specified in 
Appendix A.
Air Flow
Make sure there is at least 2 inches (or more) on 
both sides of the FN100 to allow for adequate air 
flow.
Mechanical Loading
Do not place equipment on top of a rack-mounted 
FN100.
Circuit Overloading
Make sure the power supply circuit to the rack 
assembly is not overloaded.
Grounding (Earthing)
Rack-mounted equipment should be grounded. In 
addition to the direct connections to the main power 
supplies, make sure all the other supply 
connections are also grounded.
NOTE
The FN100 may have been shipped with the rack-mount 
brackets already installed.