Enterasys fn100 Betriebsanweisung

Seite von 104
Command Syntax Conventions
Fast Network 100 User Guide
Page 2-7
A previous command can be repeated by typing 
!!
.
MAC addresses are displayed in little-endian Ethernet bit order, with 
each octet separated by a colon. For example:
FN100 > address 00:40:27:04:1a:0f
Information that you need to enter with an LCM command is enclosed 
in brackets < >. For example, you must enter a port number and an IP 
address to execute the 
ipaddr <PORT#> <IPADDR>
 command:
FN100 > ipaddr 6 192.138.217.40
Parameters that appear in all capital letters, for example 
bridge 
<PORTS>
, indicate that you must enter a value for that parameter. If a 
string of parameters is displayed between braces, for example 
<{off|on|noBPDU}>
, you must select one of the displayed options. For 
example, if you wanted to enable bridging on a port, or a range of 
ports, you would enter:
FN100 >bridge 2-4 on
The default values for filtering command field options appear in square 
brackets [ ], for example:
Type:[Entry] (Entry/Exit)>
2.6.1 Basic LCM Commands
To manage the FN100 using LCM, you first must connect the FN100 to 
an ASCII terminal or terminal emulator. See Section 2.4, Connecting the 
Local Console Manager
 for instructions.
When you want to use LCM, begin by pressing the Enter key several 
times to get the LCM prompt:
FN100 >