Installing the Side Clip GPIM
The GPIMs are installed into the module as follows:
1. Attach the antistatic strap (refer to the instructions in the antistatic wrist strap package) before 
removing the GPIM from the antistatic packaging.
2. Remove the GPIM from the packaging.
3. Hold the GPIM with the network connection port facing away from the module. The 20-pin 
connector should be facing towards the empty GPIM slot, with the wide part of the connector 
oriented up in relation to the printing on the module. See 
 to orient the GPIM 20-pin 
connector.
Figure 3-2
GPIM Connectors
4. Gently insert the GPIM (20-pin connector side) through the GPIM opening of the module. See 
The top of the GPIM must be next to the hinge side of the GPIM slot door of the 
module, as shown in 
. The door folds up and the slides engage the sides of the GPIM. 
If the GPIM does not go in easily, do not force the device. Check the orientation against 
. Push the GPIM back until the 20-pin port engages the GPIM. The latch mechanism 
engages when the GPIM connector seats properly in the port.
2549_04
Network Connection End
20-pin connector
Insertion End
RX
TX