Enterasys 5g102-06-g Installationsanweisungen

Seite von 66
Installing the Module into the 5C105 Chassis
3-8
Installation
3.2.2.2
Removing the Locking Bar GPIM
Remove a GPIM from its slot in a module as follows:
1. Attach the antistatic wrist strap (refer to the instructions in the antistatic wrist strap package) 
before removing the GPIM.
2. Remove any cables or dust protectors connected to the GPIM.
3. Locate the metal locking bar that is on the front of the GPIM.
4. Lift the metal locking bar upwards as far as it will go. See 
, View A. This will unlock 
the GPIM clips.
5. Holding the metal locking bar in the upwards position, grasp the sides of the GPIM and pull it 
out of the module.
6. If storing or shipping the GPIM, insert the dust protector into the GPIM to protect the fiber ports.
3.3
INSTALLING THE MODULE INTO THE 5C105 CHASSIS
Certain restrictions may apply when installing a module into the 5C105 chassis. Refer to the 
Release Notes for any updated information concerning installing the module into the 5C105 
chassis. The module can be installed in any of the slots (1 through 5) that are available. 
CAUTION: Do NOT remove a GPIM from a slot without unlocking the metal locking bar. 
This can damage the GPIM.
The GPIM and the module are sensitive to static discharges. Use an antistatic wrist 
strap and observe all static precautions during this procedure. Failure to do so could 
result in damage to the GPIM or module. Always leave the GPIM in the antistatic bag or 
an equivalent antistatic container when not installed.
CAUTION: Failure to observe static safety precautions could cause damage to the 
module. Follow static safety handling rules and wear the antistatic wrist strap provided 
with the 5C105 chassis.
Do not cut the non-conductive bag to remove the module. Sharp objects contacting the 
board or components can cause damage.