Enterasys 5g102-06-g Betriebsanweisung

Seite von 196
Factory Defaults
Accessing Local Management
3-5
To assign a new password, start at the Main Menu, select Management Setup Menu /Console 
Login Configuration, and enter a new password for the administrator. Passwords can consist of up 
to 11 alphanumeric characters and are not case sensitive.
3.4
FACTORY DEFAULTS
 lists the default settings for switch configuration parameters. Each parameter can be 
changed via the console menus or Telnet.
NOTE: A user is allowed three attempts to enter the correct password; on the third 
failed attempt, the current connection is terminated.
Table 3-1
Factory Default Settings
Parameter 
Default Value
Multicast Filtering
IGMP Multicast Filtering
Disabled
Port Configuration
Speed and Duplex
Admin
Auto
Enabled
Port Priority
Default Ingress User Priority
0
Spanning Tree Algorithm
Active Aging Time 
Bridge Priority 
Forward Delay
Hello Time
Max Age
Path Cost
Port Priority
Spanning Tree Protocol 
300
32768
15
2
20
4 - 1000 Mbps ports
9 - 100 Mbps ports
100 - 10 Mbps ports
128
Enabled