Enterasys 6000 Betriebsanweisung

Seite von 420
10-20
FRX/FRM 3. 3 User G uide, Rev 04
Async PVC Parameters
1
16, 32, 64 ,128, 256,  512, 1024,  2048, or 4096
.  Cannot be  greater than  the smaller 
Maximum Packet Size specified  in the port records  for both  ends of the connection.
2
Cannot be greater than the smaller 
Maximum Window  Size
 specified in the Port records 
for both ends of the connection.
Connection Priority
prioritizes this connection for intra-nodal traffic; the higher the number, the higher the 
priority. (This priority has no effect on traffic exiting a node.)
A priority is also configured in Node Defaults, as well as for each logical port, SNA 
PU, LLC2 host, Bridge Port/LLC2 Interface, IP interface, IPX interface, and SVC 
subscriber. The device processor in the node uses these priorities to help determine the 
order in which it will process protocols.
When configuring priorities, be careful to consider the types of 
traffic being routed on other connections in the node.
Subscriber Name
identifies the subscriber to the console operator. The software does not use this infor-
mation.
Logical Channel
is a logical link between the node and the subscriber.
LP/Port
specifies the LP and port at each end of the PVC.
Packet Size/Window Size
allows setting packet and window sizes for each  end  of the PVC. Generally  the same 
packet and window sizes will be configured in the port records at each end, as well as 
in the PVC record.
Table 10-5    Async PVC Parameters
Parameter
Valid Values
Default  Value
Connection Priority
0–9
0
Subscriber Name
0–31 characters
none
Logical Channel
1
1
LP
FRX4000, FRM:
 0
FRX6000:
 0–7
0
Port
0–63
0
Packet Size
128–4096 
1
128
Window  Siz e
1–7 
2
2