Enterasys 6000 Betriebsanweisung

Seite von 420
17-20
FRX/FRM 3. 3 User G uide, Rev 04
Displaying Frame Relay Backup Status
To display operational states of backup and backed-up frame relay DLCIs, press
 [E]
 at 
the Protocol Status Displays Menu (or 
[C], [F],  [E]
 from the Main Menu), then select 
from the following list and enter (when prompted) the RLP/port or group number:
A Display  States for  all Backup DLCIs  on a  Port
B Display  States for  all Primary DLCIs  on a  Port
C Display  States for  all Backup DLCIs  in a  Group
Possible states are:
Active
The DLCI is capable of passing data.
Backup Wait
(Primary DLCI only) The DLCI is down or undergoing 
IPL, but the switchover timer has not yet expired.
Backed Up
(Primary DLCI only) The DLCI has been backed up, and 
data will be routed over the backup DLCI.
Restore Wait
(Backup DLCI only) The primary DLCI is now up, but the 
switchback timer has not yet expired. (The state will return 
to 
Active
 if the Primary DLCI goes down again before the 
timer expires.)
Inactive
(Backup DLCI only) The DLCI is available.
ACK Wait/Hold
The initiating node has issued a switchover or switchback 
command and is waiting for an ACK (acknowledgment) 
from the remote node. Received data traffic will be held 
pending the ACK.
ACK Wait/Discard
The ACK (see 
ACK Wait/Hold
) has not been received 
within a pre-determined number of transmissions of the 
switchover/switchback command. Any received or held 
traffic  will be discarded.
Backup Pend/Hold
(Primary DLCI only) A backup DLCI is attempting to be 
located. Received data will be queued on the primary 
DLCI's queue.
Backup Pend/Discard
(Primary DLCI only) A backup DLCI is attempting to be 
located. Received data will be discarded.