Enterasys 6000 Betriebsanweisung

Seite von 420
18-2
FRX/FRM 3. 3 User G uide, Rev 04
The following shows an example of a two-node event routing configuration.
 
Figure 18-1    Event Reporting Configuration Example
 Alarm Buffer
Each node has a buffer where events are stored while waiting for transmission. When 
a buffer reaches the percentage of full capacity specified by the parameter 
Max Con-
gestion
, further events originating at that node are lost until the percentage of capacity 
specified by the parameter 
Min Congestion
 is reached. 
When the buffer  reaches 
Max Congestion
, the node  adds the event  message 
Beginning 
of congestion
 to the buffer. No more events are put into the buffer until it has reached 
Min Congestion
, at which time another message,
 End of congestion,  “n” events lost
, is 
put into the buffer, and all events are again put into the buffer.
When the collecting node's event buffer reaches
 Max Congestion
, events are held in the 
originating nodes' buffers until the buffers reach 
Max Congestion
 or the collecting 
node begins accepting events again.
Collecting Node ID  = 
222
Primary Alarm Output ID = 
12345
Secondary Alarm Output ID = 
C1
Network Mgmt.
Station with
Address 
12345
Printer
Node 1
Collecting Node
Optional
Monitor
COM1
Alarms from
Node 2
Node 2
Optional
Async
Terminal