Enterasys 6a000 Verweisanleitung

Seite von 276
2-158   SmartCell 6A000/ZX-250 Reference Manual
  Console Commands
PortTrafficCongestion
Use PortTrafficCongestion (port traffic congestion) to manage traffic congestion parameter for the specified port.
Operators
modify, show
Parameters
Descriptions
Parameter 
Description
Value/Field Size
Default
[PortNumber]
Port number on the switch. 
ALL, A1...A4, 
B1...B3, C1...C4, 
D1...D4
ALL
[Queue # 
Minimum/Maximum 
CellCounter]
Value programmed into the switch for minimum/ 
maximum threshold (in number of cells) for the 
specified priority queue (where “#” is 1, 2, 3, or 4). 
If the number of cells received by the switch on 
the specified priority queue for this port exceeds 
maximum threshold value, the switch discards the 
cell.
0-8192
20 (Min.)
8192 (Max.)
Operator
Parameters/Permissions
Description
modify 
porttrafficcongestion
[PortNumber] <portnumber>
[Queue#Min/MaxCellCounter]
<queue#min/maxcellcounter>
Administrator
Modifies the traffic congestion settings for a 
specified port or all ports. You can change the 
minimum and maximum buffer thresholds, in 
cells, for each priority queue on a port. Cell buffer 
memory then reserves the minimum buffer size for 
cells on the specified priority queue of that port. 
Cells are discarded when the maximum buffer 
threshold is reached.