2-208   SmartCell 6A000/ZX-250 Reference Manual
  Console Commands
Descriptions
Examples
switch_prompt # modify switchtrafficcongestion
Queue1EFCIThreshold(4096)                 :2000
Queue2EFCIThreshold(4096)                 :2000
Queue3EFCIThreshold(4096)                 :2000
Queue4EFCIThreshold(4096)                 :2000
LowEPDWatermark(10922)                    :
HighEPDWatermark(21845)                   :
RMCellMarkingEnable(1)                    :
EFCIMarkingEnable(1)                      :
switch_prompt #
switch_prompt # show switchtrafficcongestion
Switch Traffic Congestion Parameters
==============================================================================
Queue 1 EFCI Threshold                  : 2000 cells
Queue 2 EFCI Threshold                  : 2000 cells
Queue 3 EFCI Threshold                  : 2000 cells
Queue 4 EFCI Threshold                  : 2000 cells
Low EPD Threshold                       : 10922 cells
High EPD Threshold                      : 21845 cells
Switch Discard Threshold                : 31488 cells
RM Cell Marking Enable                  : ON
EFCI Cell Marking Enable                : ON
switch_prompt #
Operator
Parameters/Permissions
Descriptions
modify 
switchtrafficcongestion
[Queue#EFCIThreshold]
<queue#efcithreshold>
[LowEPDWatermark]
<lowepdwatermark>
[HighEPDWatermark]
<highepdwatermark>
[RMCellMarkingEnable]
<rmcellmarkingenable>
[EFCIMarkingEnable]
<efcimarkingenable>
Administrator
Modifies the congestion control parameters for 
the switch. For example, the EFCI thresholds 
indicate when a threshold is exceeded; the 
switch discard threshold discards cells when the 
memory buffer is full. 1 enables the parameters 
[RMCellMarkingEnable] and 
[EFCIMarkingEnable]. 0 disables them.
show 
switchtrafficcongestion
All
Displays the current traffic congestion settings 
for the switch.