Enterasys 6a000 Benutzerhandbuch

Seite von 114
4-10   SmartCell 6A000 User Guide
Events and Alarms
  Switch Administration
4.4.2
Viewing Events and Alarms
Use the 
show events
 command to view a list of the currently logged events. For example,
SmartCell ZX # show events
Index(ALL)                                :
0  MINOR EVENT        000:00:08:410
---------------------------------------------------
SAAL connection has become active, initiated by the peer
Port ID 0x0000000b
Protocol 0x02
1  MINOR EVENT        000:00:08:578
---------------------------------------------------
SAAL connection has become active, initiated by the peer
Port ID 0x0000000b
Protocol 0x02
2  MINOR EVENT        000:00:29:560
---------------------------------------------------
Sendto failed for IP address 206.61.231.153
More(<space>/q)?:
Events are displayed in the following format:
Event number — The index number of the event in the circular buffer
Event ID — A unique ID assigned to the event
Time — Time of event, in switch up-time in hours, minutes, seconds, and milliseconds
Category — Whether this event is critical, major, minor, or informational
Object — The object affected by the event (port, LEC, and so on)
Description — Brief message describing the event
Event messages can be automatically displayed on the SmartCell 6A000 console. Use the 
set EventDisplay
 
command to display events on the console as they occur:
SmartCell ZX # set eventdisplay
EventDisplay(OFF)                         : on
SmartCell ZX #
Note
Depending on the activity of your SmartCell 6A000, the appearance of events on 
the SmartCell 6A000 may be too frequent to use the SmartCell 6A000 console 
comfortably. It is recommended that you turn on the automatic display of events 
only when troubleshooting.