Enterasys 6a000 Installationsanweisungen

Seite von 52
SmartSwitch 6A000 Installation and Setup Guide   2-3
Switch Installation
Installing the Switch  
Note
All Single-Mode fiber connectors on IOMs are blue.
If the switch hardware configuration is incorrect, contact Cabletron Global Support Center immediately.
2.3
INSTALLING THE SWITCH
The SmartSwitch 6A000 is hot swappable, meaning that you can install and remove it without turning off or 
unplugging the SmartSwitch 6000 chassis. You can install as many as five switch modules in each chassis (using the 
6C205-3 power supply). In this configuration, the SmartSwitch 6A000 modules provide up to 75 user ports. Modules 
should be connected with inter-module trunks if traffic must cross between modules. Table 2-2 shows the maximum 
number of LAN and ATM switch modules that can be installed in a SmartSwitch 6000 chassis.
Note
A single 6C205-1 power supply (the older version of the 6C205-3) can support 
only two SmartSwitch 6A000s within a SmartSwitch 6000 chassis. Three 
SmartSwitch 6A000s can reside within a SmartSwitch 6000 chassis that contains 
two 6C205-1 power supplies.
Follow the instructions below to install the switch module into the chassis. Refer to Figure 2-2.
IOM-29-4-LR
155 Mbps OC-3/STS-1, SMF-LR/SC (4 port)
IOM-31-1
622 Mbps OC-12/STM-4, MMF/SC (1 port)
IOM-39-1
622 Mbps OC-12/STM-4, SMF-IR/SC (1 port)
IOM-39-1-LR
622 Mbps OC-12/STM-4, SMF-LR/SC (1 port)
IOM-67-4
45 Mbps DS-3, Coax/BNC (4 port)
IOM-77-4
34 Mbps E-3, Coax/BNC (4 port)
Table 2-2
SmartSwitch 6000 contents
Number  of  6Exxx  or  6Hxxx  modules  installed
0
1
2
3
4
5
Number  of  6A000  modules  that  can  be  added
5
4
3
2
1
0
Table 2-1
I/O module ID numbers (Continued)
Face Plate Number
Physical Specification