11
portPhyX25AdminInactivityTimer
SYNTAX:
INTEGER (
1–30
)
ACCESS:
Read/Write
STATUS:
Mandatory
DESCRIPTION:Period (in minutes) of inactivity allowed between calls.
Once the timer expires, the port is disabled until the next
call is placed, if a dial-out port, or the Disconnect Timer
expires, if a dial-in port. This variable is meaningful only
if the port is a dial port.
call is placed, if a dial-out port, or the Disconnect Timer
expires, if a dial-in port. This variable is meaningful only
if the port is a dial port.
::= { portPhyX25AdminTable.1.6 }
portPhyX25AdminDisconnectTimer
SYNTAX:
INTEGER (
1–255
)
ACCESS:
Read/Write
STATUS:
Mandatory
DESCRIPTION:Time (in seconds) a dial-in port will remain disabled after
expiration of the Inactivity Timer.
::= { portPhyX25AdminTable.1.7 }
portPhyX25AdminSetupTimer
SYNTAX:
INTEGER (
1–255
)
ACCESS:
Read/Write
STATUS:
Mandatory
DESCRIPTION:Maximum time (in seconds) within which a response must
be received by the port, after entering the Linkup state. If a
response is not received, the port enters a Failed state.
response is not received, the port enters a Failed state.
::= { portPhyX25AdminTable.1.8 }
portPhyX25AdminTrunkFlag
SYNTAX:
INTEGER { no (
1
), yes (
2
) }
ACCESS:
Read/Write
STATUS:
Mandatory
DESCRIPTION:Flag that indicates whether the port is associated with a
network trunk group. It will be disabled/enabled if the
network trunk is not operational.
network trunk is not operational.
::= { portPhyX25AdminTable.1.9 }
portPhyX25AdminTrunkGroup
SYNTAX:
OCTET STRING
ACCESS:
Read/Write