Cabletron  Relay Access Products
the transmit-receive capability indicator received in  the 
XID image from the adjacent link station.
::= { sdlcLSOperTable.1.24}
sdlcLSStatsTable (sdlcLSGroup.3)
sdlcLSStatsBLUsIn
SYNTAX:
Counter32
MAX-ACCESS: Read only
STATUS:
current
DESCRIPTION:Total  basic link units (BLUs;  frames) received from an 
adjacent SDLC link station since link station startup. At 
link station startup time, this object must be initialized to 
0
.
::= { sdlcLSStatsTable.1.1}
sdlcLSStatsBLUsOut
SYNTAX:
Counter32
MAX-ACCESS: Read only
STATUS:
current
DESCRIPTION:Total basic link units (BLUs; frames), transmitted to an 
adjacent SDLC link station since link station startup. At 
link station startup time, this object must be initialized to 
0
.
::= { sdlcLSStatsTable.1.2}
sdlcLSStatsOctetsIn
SYNTAX:
Counter32
MAX-ACCESS: Read only
STATUS:
current
DESCRIPTION:Total octets received from an adjacent SDLC link station 
since link station startup. This object covers the address, 
control, and information field of I-Frames only. At link 
station startup time, this object must be initialized to 
0
.
::= { sdlcLSStatsTable.1.3}
sdlcLSStatsOctetsOut
SYNTAX:
Counter32
MAX-ACCESS: Read only
STATUS:
current
DESCRIPTION:Total octets transmitted to an adjacent SDLC link station 
since link station startup. This object covers the address,