Enterasys 6000 Verweisanleitung

Seite von 238
200
Cabletron  Relay Access Products
Novell IPX MIB
Basic System Table (ipx.1.1)
ipxBasicSysNetNumber
SYNTAX:
NetNumber
ACCESS:
Read/Write
STATUS:
Mandatory
DESCRIPTION:Network number portion of the IPX address of this system.
::= {ipxBasicSysEntry.3}
ipxBasicSysNode
SYNTAX:
OCTET STRING  (SIZE(6))
ACCESS:
Read/Write
STATUS:
Mandatory
DESCRIPTION:The node number portion of the IPX address of this 
system.
::= {ipxBasicSysEntry.4}
ipxBasicSysName
SYNTAX:
OCTET STRING  (SIZE(0.48))
ACCESS:
Read/Write
STATUS:
Mandatory
DESCRIPTION:The readable name for this system.
::= {ipxBasicSysEntry.5}
ipxBasicSysInReceives
SYNTAX:
Counter
ACCESS:
Read only
STATUS:
Mandatory
DESCRIPTION:The total number of IPX packets received, including those 
received in error.
::= {ipxBasicSysEntry.6}
ipxBasicSysInHdrErrors
SYNTAX:
Counter
ACCESS:
Read only
STATUS:
Mandatory
DESCRIPTION:Number of IPX packets discarded due to errors in their