Enterasys 6e128-26 Betriebsanweisung

Seite von 180
Chapter 5: Local Management
5-22
6E128-26, 6E138-25, 6E129-26 and 6E139-25 User’s Guide
If the time entered is within the 1 to 30 minutes range, the Event Message 
Line at the top of the screen displays “SAVED OK”. If the entry is not 
valid, Local Management does not alter the current setting, but it does 
refresh the Screen Lockout Time field with the previous value.
5.7.7
Setting the Operational Mode
To set the Operational Mode, proceed as follows:
1.
Use arrow keys to highlight the Operational Mode field.
2.
Press the SPACE bar to step to the appropriate operation mode, 
(802.1D SWITCHING or 802.1Q SWITCHING).
3.
Use the arrow keys to highlight the SAVE command at the bottom of 
the screen and press ENTER. The warning screen shown in 
Figure 5-10
Operational Mode Warning Screen
4.
Use the arrow keys to highlight the YES command and press ENTER. 
The changes are saved, and all the modules installed in the chassis 
reboot.
WARNING!
1666
YOU HAVE ELECTED TO SAVE THE OPERATIONAL MODE FOR
THE WHOLE CHASSIS. THIS WILL CAUSE ALL OF THE
BOARDS IN THE CHASSIS TO REBOOT.
ARE YOU SURE YOU WANT TO SAVE THE NEW OPERATIONAL MODE?
NO
YES