Yamaha RX-Z11 Betriebsanweisung

Seite von 177
Optimizing the speaker setting for your listening room (YPAO)
49
 En
Prepara
tion
8
Once all measurement items are set successfully, 
following display appears in the menu screen.
In this menu, you can perform the following operations:
• Press 9n and select “Setup” to set the measured values.
• Press 9k and select “Retry” to retry the automatic setup 
procedure. This unit starts the automatic setup procedure 
immediately again.
• Press 9h and select “Detail” to view information about 
measurement results and warning messages. In the 
information display, press 9k / n repeatedly to toggle 
between the parameters. See page 50 for details.
• Press 9l to cancel the measurement results and exit from 
the automatic setup menu.
9
Press I
MENU to turn off the GUI menu.
• After you have completed the automatic setup procedure, be sure to 
disconnect the optimizer microphone.
• The optimizer microphone is sensitive to heat. Keep it away from direct 
sunlight and do not place it on top of this unit.
■ Reviewing the result of the automatic setup
Use this feature to review the result of the automatic setup.
1
Set the operation mode selector to F
AMP and then 
press I
MENU to turn on the GUI screen.
2
Press 9k / n repeatedly and then 9h to select 
Auto Setup”.
3
Press 9k to select “Information”.
4
Press 9h and then 9k / n repeatedly to select the 
desired check items.
If error or warning messages appear...
When this unit detects potential problems during the 
automatic setup procedure, error or warning messages 
appears in the result display. See the “Auto Setup” section 
in “Troubleshooting” on page 152 for a complete list of 
error or warning messages and proper remedies.
Press 9l to view the detailed information of the error or 
warning messages.
Notes
Error or warning messages
Error or warning messages
Reload:ENTER