Zhone 7995 Betriebsanweisung
A. Configuration Options
7990-A2-GB20-20
September 2004
A-19
Stop Bits
Possible Settings: 1, 1.5, 2
Default Setting: 1
Default Setting: 1
Specifies the number of stop bits for the communication port.
Stop Bits appears only when Port Use is set to Terminal.
1 – One stop bit.
1.5 – One and one half stop bits.
2 – Two stop bits used.
Ignore Control Leads
Possible Settings: Disable, DTR
Default Setting: Disable
Default Setting: Disable
Specifies whether DTR is used.
Ignore Control Leads appears only when Port Use is set to Terminal.
Disable – Control leads are treated as standard.
DTR – DTR is ignored.
Login Required
Possible Settings: Enable, Disable
Default Setting: Disable
Default Setting: Disable
Specifies if an ID and password are required to access the asynchronous terminal
interface on the communication port. Login IDs are created with a password and access
level. Refer to
interface on the communication port. Login IDs are created with a password and access
level. Refer to
Login Required appears only when Port Use is set to Terminal.
Enable – Login ID and password are required to access the asynchronous terminal
interface.
interface.
Disable – No Login ID and password are required to access the asynchronous terminal
interface.
interface.
Port Access Level
Possible Settings: Administrator, Operator
Default Setting: Administrator
Default Setting: Administrator
Specifies the highest level of access allowed when accessing an ATI session through a
Telnet session.
Telnet session.
Port Access Level appears only when Port Use is set to Terminal.
Administrator – This is the higher access level, permitting full control of the unit. Access
level is determined by the Login ID. If Telnet Login Required is disabled, the session
access level is Administrator.
level is determined by the Login ID. If Telnet Login Required is disabled, the session
access level is Administrator.
Operator – This is the lower access level, permitting read-only access to status and
configuration screens.
configuration screens.
Table A-7.
Communication Port Options (2 of 3)