3. Use a combination wrench and pliers to attach the flexible 
connector to the adapters. Check that connector is not 
kinked. 
Complete Connection
1. Locate gas pressure regulator in the broiler.
IMPORTANT: Do not remove the gas pressure regulator.
2. Check that the gas pressure regulator shutoff valve is in the 
“on” position.
3. Open the manual shutoff valve in the gas supply line. The 
valve is open when the handle is parallel to the gas pipe.
4. Test all connections by brushing on an approved 
noncorrosive leak-detection solution. Bubbles will show a 
leak. Correct any leak found.
5. Close the broiler door.
6. Remove cooktop burner caps and grates from parts 
package. Align notches in burner caps with pins in burner 
base. Burner caps should be level when properly positioned. 
If burner caps are not properly positioned, surface burners 
will not light. Place burners, burner caps and grates on the 
cooktop.
7. Plug into a grounded 3 prong outlet.
Verify Anti-Tip Bracket Location
1. Check that the anti-tip bracket is installed:
Look for the anti-tip bracket securely attached to the floor.
Slide the range back so the rear range foot is under the anti-
tip bracket.
Level Range
1. Place rack in oven. 
2. Place level on rack and check levelness of range, first side to 
side; then front to back.
3. If range is not level, pull range forward until rear leveling leg is 
removed from the anti-tip bracket. Use 
³⁄₈" drive ratchet and 
wrench or pliers to adjust leveling legs up or down until range 
is level.
4. Push range back into position.
5. Check that rear leveling leg is engaged in anti-tip bracket.
NOTE: Range must be level for satisfactory baking performance.
A. Pressure regulator 
connection fitting
B. Use pipe-joint compound
C. Adapter
D. Flexible connector
E. Adapter
F. Use pipe-joint compound
G. Manual shutoff valve
H. ½" or ¾" gas pipe
A. Closed valve
B. Open valve
C
E
G
H
A
D
F
B
A
Front View
Front View
Side View
Shutoff valve
Front
“ON” Position
A
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING