Broan-NuTone e64e36ss Benutzerhandbuch

Seite von 48
- 5 -
1. SELECT BLOWER OPTION AND INSTALLATION TYPE
1.2 D
UCTED
I
NSTALLATION
The Broan Elite E64000 Series range hood includes many configurations: hood with single or double internal blowers 
(included with the hood), or hood using external blowers. For hood using external blowers, the Broan Elite E64000 Series 
must be installed with in-line blower models HLB3, HLB6, HLB9 or HLB11, or exterior blower model 331H, 332H, 335 or 
336 only. Other blowers cannot be substituted. (Blowers sold separately).
Plan where and how the ductwork will be installed. 
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1, 2, 3, 4, 10 and up of 
this manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. If using 7”, 8” or 10” 
round ducts, use a transition (internal blower(s) only). Use 2” duct tape to seal duct joints.
The minimum hood distance above cooktop must not be less than 24’’. A maximum of 30” above cooktop is highly 
recommended for best capture of cooking impurities. 
Distances over 30” are at the installer and users discretion.
Hood
3¼” x 10” duct
or 7” or 8” round duct
Roof cap
Wall
cap
HH0085A
24” minimum above
cooking surface
3¼” x 10” to 7” or
3¼” x 10” to 8” transition
(if using round duct)
SINGLE INTERNAL BLOWER 
TYPICAL DUCTWORK
Hood
10” round duct
Roof cap
Wall
cap
4½” x 18½” to 10”
transition
HH0086A
24” minimum above
cooking surface
DOUBLE INTERNAL BLOWERS 
TYPICAL DUCTWORK
HH0087A
Hood
10” round duct
Exterior blower
24” minimum above
cooking surface
MODEL 331H, 332H, 335 OR 336 
EXTERIOR BLOWER
TYPICAL DUCTWORK
In-line blower
10” round duct (except
HLB3, 8” round duct)
HH0092A
24” minimum
above cooking
surface
Roof cap
Wall
cap
Hood
MODEL HLB3, HLB6, HLB9 OR HLB11 
IN-LINE BLOWER TYPICAL DUCTWORK
1.1 N
ON
-D
UCTED
I
NSTALLATION
For a non-ducted installation, a non-duct kit ANKE60 Series (sold separately) must be installed. For maximum effectiveness,
we recommend installing this kit with a single (internal) blower hood. The kit fits hoods from 30-inch width up to 48-inch
width. See installation instructions included with the non-duct kit ANKE60 Series.