87
MSI/plessey 
Read: Format   
Data Digits
(Variable)
Checksum1
(Optional)
Checksum2
(Optional)
Checksum Verification: The MSI/Plessey has one or two 
optional checksum digits.    The checksum is presented 3 
kinds of method Mod10, Mod10/10 and Mod 11/10.    The 
checksum1 and checksum2 will be calculated as the sum 
module 10 or 11 of the data digits. 
Checksum Transmission: By setting Enable, checksum1 
and checksum2 will be transmitted upon your selected 
checksum verification method. 
Max./Min. code length: Refer to Max./Min. code length of 
Code-39. 
Truncate leading/ending: Refer to Truncate leading/ending 
of UPCA. 
Code ID setting: Refer to Code ID setting of UPCA. 
Insertion group number selection: Refer to page 51 
Insertion group number selection of UPCA. 
 
 
 
 
Option Bar Code 
Option 
Alphanumeric 
Entry 
Read 
Disable 
Enable 
00
 
01 
 
Checksum 
Verification 
Disable 
Mod 10 
Mod 10/10 
Mod 11/10 
00 
01
 
02 
03 
 Program