Cleveland ogb-20.20 Benutzerhandbuch

Seite von 81
BU 18
-A13
1
2
BK
 1
8
WH
 1
8
3
4
RD
 1
8
D5
-A
10
:X
10
:12
-A
10
:X
10
:1
1
D4
-A
10
:X
10
:1
0
D4
-A
10
:X
10
:9
D4
IDENTIFICATION MODULE
-B
5
P
R
O
B
E
 BY
PA
SS
10
3
BU 18
-M3.2
-M3.1
COOLING FANS
-H5.2
-X10
21
OVEN LAMP
-H5.1
X2
X1
X2
X1
CONDENSER
-Y1
A2
A1
-A12
CABLE CONNECTION SM ON BM 
CONTROL 500
BK
M
RD
BK
M
RD
PICTO
-A10
X18:
1
RD 18
-F2.1
1A
21
RD
 1
8
-W1
3
1
X19:
CONTROL MODULE
SM 5010
10
8
9
X17:
6
7
5 4
1 2
2 1
12 11
BM 5010
OPERATION MODULE
X39: 1
(OPTION)
MODULE
-A11
PR
OBE C
O
NDENS
ER
RD
YL
RD
-B
3
-Y21
-Y3
-Y2
-Y10
-Y20
BU 18
DEHUMIDIFICATION
A2
INJECTION
A2
WATER CLEANING
A2
CLEANING AGENT
CLEANING AGENT
RINSING AGENT
-Y22
N
L
NL
-Y23
N
L
X14:
PUMP/CLEANING AGENT
COMPARTMENT RINSE VALVE
STEAM GEN OVER TEMP
STEAM GEN PUMP
9
RD
 1
8
A1
RD
 1
8
A1
12
4 5 6 7
X10:
8 9
11
10
8
9
6
7
X16:
3
4
5
2 1
MOTOR
 OVE
R
 T
EMP
MO
TO
R O
V
ER
 T
E
M
P
M
O
TO
R
 / 
RIGHT
MOTOR
 / 
LE
FT
MOTOR
 / 
FA
ST
M
O
TO
R
 / 
S
LOW
1 2 3 4
X11:
5 6
14
12
13
10
11
-X1
0:3
1
/2
.B3
A1
L1
- 11
0/
12
0-
IN
B
U
R
N
ER SU
PPLY
 
HO
T AI
R
8
7
OVE
N
 L
AM
P
1 2 3 4
X12:
7
8
5
6
4 3 2 1
X13:
DE
HU
M
IDI
CA
TI
ON
/V
A
LV
E
CO
ND
EN
S
O
R/
VA
LV
E
GE
M FIL
L/
VALVE
5 6 7
8
9
10
6
7
P>
PR
OBE
 O
VEN
GN
YL
YL
RD
WH
-B
6
GN
GN
G
NRD
GN
BU
-B1
0
KT
M
CT
C
RD
 1
8
15
6
15
7
RD
 1
8
RD
 1
8
RD
 1
8
13
14
-S7
14
13
RD
 1
8
RD
 1
8
RD
 1
8
-X10
13
3
13
4
13
6
PUMP/RINSE
 2
 1
4
3
5
4
5
2
3
9
7
6
8
10
1
/3.A8
-K10:14
-A
13
:X
1:
2
/2.E
3
-A
13
:X
1:
1
-A
20
:X
28
:5
-A
20:X
28
:3
-A
20
:X
28
:4
-A
20:X
28
:6
-G
1:
0V
-G
1:
12
V
/4.E
3
/2
.E3
A8
A8
-A
13
:X
1:
4
-A
13
:X
1:
3
A8
A8
-A20:X20:1
-X10:34
/5.A4
/4.E5
-X10
RD 18
33
/2.F8
N
/5.A1
12V
DC-
 F
AN
ID
M (
W
H
)
ID
M (
RD)
ID
M (
B
U
)
RE
SE
T
Tx
D
_12V
ID
M (B
K)
0V
DC
 IN
Rx
D_
12
V
12
VD
C I
N
12V
DC+
 F
AN
GN
D
X15:
GN
D
GN
D
RESET
P
R
ES
. SW
0V
DC
 IN
Tx
D
_12V
R
xD_12V
DO
OR
 SW
/4.E
3
/4.E
3
/4.E
3
(JUMPER)
BK 18
RD 18
-X10
GND
100
F
E
D
C
B
A
1
2
3
4
5
6
7
8
F
E
D
C
B
A
1
2
3
4
5
6
7
8
CLEVELAND RANGE, LLC
1333 East 179th St., Cleveland, Ohio 44110-2574
VOLTAGE: 
WATTAGE: 
CURRENT: 
DATE
SHEET        OF 
REV
DRAWN BY
DRAWING NO.
THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVELAND RANGE.
THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL OF CLEVELAND RANGE.
TITLE
SIZE
B
WIRING DIAGRAM
OGS 20.20
300498
110-120
-
22.5A
DRL
12-02-05
3
9
A
WIRING DIAGRAM
-N22:X1:12
/7.A4
-U22:X1:2
/7.A4
CLEANING OPTION ONLY
-X10:23
FBS 2-6
/5.A1
-X10:23
-S2
-X10
DOOR MAGNET SWITCH
/2.B
4
-X
13
.5:3
-X
13
.5:2
/2
.B4
-X
13
.5:1
/2
.B4
CLEANING PRESSURE SWITCH
CLEANING OPTION ONLY
BU 18
BN 18
BN 18
BU 18
GN 18
1
1
-
+ -
+
-
+ - + - +
GN
D
N.O
.
COM
PRESSURE SWITCH
-S3
INJECTION
P
R
ES. SW
IN
JECT
IO
N
67