Example of end -to-end test 
•  Incoming 64k all bear: the instrument waits for a call from a remote device. 
As soon as a call is received, the instrument, without performing any 
compatibility control of the called profile, answers automatically and starts to 
generate the PRBS and measure the BER according to the pseudorandom 
sequence set. 
 
In ‘Incoming 64k all bear’, the test equipment can be used as an 
automatic answer remote machine, which activates every kind of 
incoming call an performs a BER test with generation and 
measure of the PRBS sequence.  
Band: To select the bandwidth on which perform the test. Only BASIC ACCESS and 
LEASED LINE mode. 
 
When the device is set in PRI or PRI(CRC4) it is possible to 
configure, from COMMON SETUP page, the channels’ 
mapping on which carry out the test. The device supports BER 
test in Nx64 mode. 
Bit Sequence: Set the pseudo-random bit sequence to be used from the list or 
define your own pattern.   
Pass/Fail Test: Choose the BER value. This value is used to determine the pass or 
fail test condition. Use E-7 (10-7) when no other value is requested. The G.821 value 
calculates the acceptability threshold according to the performance target expected 
by the G.821 recommendation. The HRX(%) parameter modifies such threshold.     
Error Injection: Insert the number of wrong bits which the device sends on line. It is 
possible to use both manual and automatic mode. In automatic mode, you need to 
insert the BER value to be sent. 