Dwin duovision Betriebsanweisung

Seite von 42
34
DuoVision™ RS-232 Control
The RS-232 interface for the DuoVision
 System can be operated from any ter-
minal, such as a Windows based PC running HyperTerminal.
Communication Port Set-Up  Connector pin-out
Baud Rate: 
9600  
3  TX (Transmit Data)
Parity:  
none 
2  RX (Receive Data)
Stop bits:  
5  GND (Signal Ground)
Num. of bits: 
8 bits
Flow control:   none
Each command is enclosed in the 
[ ]
 character envelope.
Note: Sequential commands must be separated with proper delays.
Any command followed by 
POWER ON
 must be delayed 10 seconds.
Any command followed by 
INPUT SELECT
 must be delayed 1 second.
The following table lists the commands available: 
[LH] 
Lamp Hours 
Transmits Lamp Hours in ASCII characters.
Display 1
[I11] 
Video 1
[I12] 
Video 2
[I13] 
S-Video 1
[I14] 
S-Video 2
[I15] 
Component 1
[I16] 
Component 2
[I17] 
RGB 1
[I18] 
RGB 2
[I19] 
DVI 1
[I10] 
DVI 2
Display 2
[I21] 
Video 1
[I22] 
Video 2
[I23] 
S-Video 1
[I24] 
S-Video 2
[I25] 
Component 1
[I26] 
Component 2
[I27] 
RGB 1
[I28] 
RGB 2
[I29] 
DVI 1
[I20] 
DVI 2
INPUT SELECT
Display 1
[PON1] 
Power on
[POFF1]  
Power off
[LH]
Display 2
[PON2] 
Power on
[POFF2]  
Power off
POWER CONTROL
Display 1
[F11] 
Standard
[F12]  
Anamorphic/HD
[F13]  
Letterbox
[F14]  
Custom
Display 2
[F21] 
Standard
[F22]  
Anamorphic/HD
[F23]  
Letterbox
[F24]  
Custom
FORMAT SELECT