F13 Series Ice Cream Cabinets Service and Installation Manual
3
For customer service, call (800) 733-8829, (800) 773-8821, (989) 773-7981,  Fax (989) 773-3210, www.delfield.com
RECEIVING AND INSPECTING THE EQUIPMENT
INSTALLATION
Location
These units are for indoor use only.  Be sure the 
location chosen has a floor strong enough to support 
the total weight of the cabinet and contents. Reinforce 
the floor if necessary to provide for maximum loading.
For the most efficient refrigeration, be sure to provide 
good air circulation inside and out.
Outside cabinet: Be sure that the unit has access to 
ample air. It is suggested that the rear of the unit be 
no less than two inches from any wall, partition or any 
other object which will restrict exhaust air flow. Avoid 
hot corners and locations near stoves and ovens.
Leveling
A level cabinet looks better and will perform better 
because the cabinet will not be subject to undue strain.
Electrical connection
Refer to the amperage data on the serial 
tag and your local code or the National 
Electrical Code to be sure the unit is 
connected to the proper power source. 
A protected circuit of the correct voltage 
and amperage must be run for connection 
of the line cord or permanent connection 
to the unit.
Self-contained models are provided with an a 
ON/OFF 
power switch located directly behind the louvered panel 
of the compressor section. Also located behind the 
louver panel in the compressor section is the On/Off 
switch for the heater wires.  On the remote units the 
thermostat may be provided with an 
OFF position which 
shuts off only the solenoid valve.
The power switch must be turned to the 
OFF position and power disconnected 
whenever doing the following:
1) Performing maintenance functions.
2) Cleaning the refrigerated cabinet area.
3) Performing service or repair functions.
Under no circumstances should the unit 
be operated without the louvered panel in 
place!
If receptacles are to be mounted in the unit backsplash, 
the power must be supplied from a separate electrical 
source and installed in accordance with the national 
Electrical Code and local electrical codes.
Even though most equipment is shipped crated, care 
should be taken during unloading so the equipment is 
not damaged while being moved into the building.
1.  Visually inspect the exterior of the package and 
skid or  container.  Any damage should be noted 
and reported to the delivering carrier immediately.
2.  If damaged, open and inspect the contents with 
the carrier.
3.  In the event that the exterior is not damaged, yet 
upon opening, there is concealed damage to the 
equipment notify the carrier.  Notification should 
be made verbally as well as in written form.
4.  Request an inspection by the shipping company 
of the damaged equipment.  This should be done 
within 10 days from receipt of the equipment.
5.  Check the lower portion of the unit to be sure legs 
or casters are not bent.
6.  Also open the machine compartment housing and 
visually inspect the refrigeration package.  Be sure 
lines are secure and base is still intact.
7.  Freight carriers can supply the necessary damage 
forms upon request.
8.  Retain all crating material until an inspection has 
been made or waived.
Uncrating the Equipment
First cut and remove the banding from around the 
crate.  Remove the front of the crate material, use 
of some tools will be required.  If the unit is on legs 
remove the top of the crate as well and lift the unit off 
the skid.  If the unit is on casters it can be "rolled" off 
the skid.