Main Tab 
173 
E-EQ-MX7RG-H 
 
MX7 Reference Guide 
If “Send Key Messages …” is checked any data scan is converted to keystrokes and sent to the 
active window. When this box is not checked, the application will need to use the set of LXE 
Scanner APIs to retrieve the data from the scanner driver. Note that this latter method is 
significantly faster than using “Wedge”.  
Disable “Enable Internal Scanner Sound” when you want an application, not the scan engine or 
the CE operating system, to control scanner audible notifications. Adjust the settings and tap the 
OK box to save the changes. The changes take effect immediately. 
Main Tab 
Access: 
 | Settings | Control Panel | Scanner | Main tab 
Factory Default Settings 
Main 
Port 1 
Internal 
Port 2 
Disabled 
Port 3 
Disabled 
Send key messages (WEDGE) 
Enabled 
Enable Internal Scanner Sound 
Enabled 
*  Good Scan Vibration 
Disabled / Long 
*  Bad Scan Vibration 
Disabled / Long 
Figure 4-3  Scanner Control / Main 
*  Vibration checkboxes previously on the Main tab panel are located on the Vibration tab panel. 
Adjust the settings and tap the OK box to save the changes. The changes take effect immediately.  
Parameter Function 
Port  
Port 1 – Internal. Radio button allows scanner input/output on Port 1 
(scan key or trigger). 
Port 2 – Output is enabled when COM1 is enabled on this port. 
Port 3 - Output is enabled when COM1 is enabled on this port. 
Send Key Messages 
(WEDGE) 
When Send Key Messages (WEDGE) is checked any data scan is 
converted to keystrokes and sent to the active window. When this box is 
not checked, the application will need to use the set of LXE Scanner 
APIs to retrieve the data from the scanner driver. Note that this latter 
method is significantly faster than using “Wedge”.