LXE mx6 Verweisanleitung

Seite von 338
AppLock Error Messages 
239 
E-EQ-MX6RG-E 
 
MX6 Reference Guide 
Message 
Explanation and/or corrective action 
Level 
Timeout looking for app window 
After the application is launched, AppLock must wait 
until the application has initialized itself before 
proceeding. The application did not start successfully 
and AppLock has timed out. 
LOG_ERROR 
ToUser after admin, not at boot 
The user mode switch is attempted when the device 
boots and after the administrator presses the hotkey. The 
mode switch is being attempted after a hotkey press. 
LOG_EX 
ToUser after admin-app still open 
The switch to user mode is being made via a hotkey 
press and the administrator has left the application open 
and has not made any changes in the configuration. 
LOG_EX 
ToUser after admin-no app or cmd 
line change 
If user mode is being entered via a hotkey press, the 
administrator may have left the configured application 
open. If so, AppLock does not launch the application 
again unless a new application or command line has 
been specified; otherwise, it just locks it. 
LOG_EX 
Unable to move desktop 
The desktop is moved when switching into user mode. 
This prevents them from being visible if the application 
is exited and restarted by the timer. This error does not 
affect the screen mode switch; processing continues. 
LOG_ERROR 
Unable to move taskbar 
The taskbar is moved when switching into user mode. 
This prevents them from being visible if the application 
is exited and restarted by the timer. This error does not 
affect the screen mode switch; processing continues. 
LOG_ERROR 
Unhook taskbar wndproc failure 
AppLock could not remove its control of the taskbar. 
This error does not affect AppLock processing 
LOG_ERROR 
Unhook wndproc failure 
AppLock could not remove the hook that allows 
monitoring of the application. 
LOG_ERROR 
Unhooking taskbar 
In administration mode, the taskbar should return to 
normal operation, so AppLock’s control of the taskbar 
should be removed. 
LOG_EX 
Unhooking wndproc 
When the administrator leaves user mode, the device is 
fully operational; therefore, AppLock must stop 
monitoring the locked application. 
LOG_EX 
WM_SIZE adjusted 
This message denotes that AppLock has readjusted the 
window size. 
LOG_EX 
X after Ctrl+L 
Processing the backdoor entry. 
LOG_EX 
Ret from password <#> 
Return value from password dialog. 
LOG_EX 
Decrypt data len <#> 
Length of decrypted password. 
LOG_EX 
Window handle to 
enumwindows=%x 
The window handle that is passed to the enumeration 
function. This message can be used by engineering with 
other development tools to trouble shoot application 
lock failures. 
LOG_EX 
WM_WINDOWPOSCHG 
adjusted=%x 
Output the window size after it has been adjusted by 
AppLock 
LOG_EX