LXE mx6 Verweisanleitung
252
Symbologies
MX6 Reference Guide
E-EQ-MX6RG-E
UPCA
Syntax UPCA=p1,p2,p3,p4,p5,p6,p7
Example UPCA=1,0,0,0,0,0,0
Example UPCA=1,0,0,0,0,0,0
Pn Default
Valid
Description
1
1
1 enable 0 disable
Decode UPCA barcode
2
0
1 enable 0 disable
Transmit check digit
3
0
1 enable 0 disable
Transmit number system
4
0
1 enable 0 disable
Transmit 2-digit addenda
5
0
1 enable 0 disable
Transmit 5-digit addenda
6
0
1 enable 0 disable
Only decode barcodes with 2- or 5-
digit addenda
digit addenda
7
0
1 enable 0 disable
Insert space between code and
addenda
addenda
Note: An EAN 13 decoding algorithm will also decode UPCA labels. For correct operation,
either disable the EAN 13 symbology when using UPCA labels or configure the EAN 13
settings to match the UPCA settings.
settings to match the UPCA settings.
UPCE0
Syntax UPCE0=p1,p2,p3,p4,p5,p6,p7,p8
Example UPCE0=1,0,0,0,0,0,0,1
Example UPCE0=1,0,0,0,0,0,0,1
Pn Default
Valid
Description
1
1
1 enable 0 disable
Decode UPCE0 barcode
2
0
1 enable 0 disable
Transmit check digit
3
0
1 enable 0 disable
Transmit number system
4
0
1 enable 0 disable
Expand version E to 12-digit UPCA
format
format
5
0
1 enable 0 disable
Transmit 2-digit addenda
6
0
1 enable 0 disable
Transmit 5-digit addenda
7
0
1 enable 0 disable
Only decode barcodes with 2- or 5-
digit addenda
digit addenda
8
0
1 enable 0 disable
Insert space between code and
addenda
Note: UPCE0 and UPCE1 must be configured identically for correct operation.
UPCE1
Syntax UPCE1=p1,p2,p3,p4,p5,p6,p7,p8
Example UPCE1=1,0,0,0,0,0,0,1
Example UPCE1=1,0,0,0,0,0,0,1
Pn Default
Valid
Description
1
1
1 enable 0 disable
Decode UPCE1 barcode
2
0
1 enable 0 disable
Transmit check digit
3
0
1 enable 0 disable
Transmit number system
4
0
1 enable 0 disable
Expand version E to 12-digit UPCA
format
format
5
0
1 enable 0 disable
Transmit 2-digit addenda
6
0
1 enable 0 disable
Transmit 5-digit addenda
7
0
1 enable 0 disable
Only decode barcodes with 2- or 5-
digit addenda
digit addenda
8
0
1 enable 0 disable
Insert space between code and
addenda
addenda