Fuse Replacement for the VX7 
VX7 User’s Guide 
E-EQ-VX7OGWW-H 
Fuse Replacement for the VX7 
The VX7 uses a 100V, 10A time delay  (slow blow), high current interrupting rating fuse that is 
externally accessible and user replaceable. Should it need replacement, replace with same size, 
rating and type of fuse – Littlefuse 0234010 or Optifuse MSC-10A (5x20mm). 
3
2
1
T10A, 125V
INPUT:
12-80VDC
6A 72W
AUDIO
ETHERNET /
USB
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY
INTERFERENCE RECEIVED, INCLUDING INTERFERENCE
THAT MAY CAUSE UNDESIRED OPERATION.
This Class A digital apparatus complies with
Canadian ICE-003.
Cet appareil num
de la Classe A est
confirme l
érique
orme NMB-003 du Canada
à n
CAUTION: For continues protection against risk of fire, 
replace only with same type and rating of fuse.
ATTENTION: Pour ne pas compromette la preotection
contre les risques d'incendie, remplacer par un fusible
de mmes types de mmes caractristques nominales.
ê
ê
é
TENT 5862393
 
1. Fuse 
2.  Twist in this 
direction to 
remove 
3.  Twist in this 
direction to insert
 
Figure 69  Fuse Replacement 
1. 
Turn the VX7 off and disconnect the power cable from the VX7. 
 
Caution: 
!
 
Fuse has voltage on it even when power is off.  Always disconnect input 
power before changing fuse. 
2. 
While holding the VX7 over a level surface, push the fuse cover in and twist it one 
quarter turn counterclockwise. A flat head screwdriver may be used to twist the fuse 
cover. 
3. 
Remove the fuse. 
4. 
Discard the fuse and place a new fuse in the holder. 
5. 
Push the fuse in and twist it clockwise one quarter turn. 
6. 
Reconnect the power cable to the VX7.