TROUBLESHOOTING GUIDE
Problem
Possible Source
Check
Solution
No Hot Water
1. Tank heater
2. Hi-limit thermostat 
or main thermostat
1. Check the voltage at the tank 
heater terminals. Voltage should be 
120V (230V for E models). Check 
serial tag for proper voltage.
2. Check the voltage between the 
white wire on the tank heater 
terminal and the incoming terminal 
(black wire) on the hi-limit 
thermostat, then the outgoing 
(black wire) terminal on the hi-limit 
thermostat.
1. (A) If correct voltage is present at the tank heater 
terminals and water is not being heated, replace tank 
heater.
(B) If voltage is not present at tank heater terminals, 
refer to step 2.
(C) If incorrect voltage is present at tank heater 
terminals, check voltage at outlet.
2. (A) If voltage is present on incoming terminal on the 
hi-limit thermostat but not on the outgoing terminal, 
replace hi-limit thermostat. 
(B) Check voltage between black and white wire on 
receptacle. If voltage is not present check outlet or 
circuit breaker. 
(C) If voltage is not present on incoming terminal of 
hi-limit thermostat, replace main thermostat.
Steaming or
Spitting Around
Funnel
1. Main thermostat
2. High altitude
1. Thermostat contact stuck or out of
calibration
2. For altitude above 5,000 feet (1,500m)
1. (A) Adjust thermostat to lower temperature setting.
(B) Thermostat should be calibrated or replaced.
Dripping
1. Not siphoning properly
2. Leaky fill valve
1. Water should flow from sprayhead freely
2. Turn off water supply to see if 
dripping stops
1. (A) Clean sprayhead holes
(B) Check tightness of sprayhead tube.
(C) Check brass elbow in tank for debris
2. Replace or repair inlet valve as needed
Dry Coffee
Remaining on
Brew Basket
1. Filters
2.  Not siphoning properly
3. Improper loading of 
brew basket
1. Are correct filters being used
2. Refer to “dripping” step 1
3. Filter and coffee in brew basket 
1. Use correct filter
2. Refer to “dripping” step 1
3. Filter should be centered in brew basket and 
coffee bed should be level.
Warmer Station
1. Warmer - defective
2. Warmer On/Off switch
3. Bad harness
1. Voltage at warmer terminals should 
be 120V (230V for E models).
2. If voltage is not present on warmer 
terminals, check continuity of switch
3. Check connections between harness 
and switch, and between switch and 
warmer.
1. If voltage is present on terminals, but warmer is 
not heating, replace warmer.
2. If switch does not make and break continuity 
when turned on and off, replace switch.
3. All connections should be tight.
Overflowing
1. Receiving container 
not completely empty 
at start of brew cycle.
2.  Not siphoning properly
3. Adjust timer
1. Operating instructions
2.  Refer to “dripping” step 1.
3. Check valve on-time with watch
1. Always start brew cycle with empty container.
2. Refer to “dripping” step 1.
3. Refer to “Brew Volume Adjustment” section
Low Pot Level
1. Adjust timer 
1. Check valve on-time with watch
1. Refer to “Brew Volume Adjustment” section
Excessively Long
Brew Times
1. Lime scale build-up
1. Remove spray head deflector and check 
nozzle.
1. Delime machine.
Little or No Water
From Faucet
1. Lime scale build-up
2. Clogged inlet valve
Be sure water is turned on.
1. Delime heat exchanger.
2. Replace or repair inlet valve.
If you still need help, call an authorized dealer in your area or Grindmaster Corporation’s Technical Service Department. You can reach
Technical Service at (502) 425-4776 or (800) 695-4500 (USA and Canada only) Monday - Friday, 8:00 AM - 8:00 PM EST.
Please have the model and serial number ready so that accurate information can be given.
Prior authorization must be obtained from Grindmaster Corporation’s Technical Service Department for all warranty claims.