Ricoh 480W Verweisanleitung

Seite von 234
 PLOTBASE 
DIRECTORY 
than one plot file. 
In most cases theses files are automatically created by the 
PLOTCLIENT programs and put into the spool folder. 
Both types of files may also be saved manually in the spool 
folder accompanied by the plot files. This is desscribed in the 
chapter "manual copy of SSL and CFG jobs". 
Note:  CFG- and SSL-files contain the parameters for 
the print-outs. CFG files are sent with single drawing-
files, whereas SSL-files define the properties of 
complete drawing sets. Normally, these files are 
created by client-programs automatically. Both file 
types can be created also by yourself. To do so you 
have to use the CFG- and SSL-commands, which are 
described in the Technical Manual.  
When reading the SSL files and starting the jobs, RW-480 
PLOTBASE proceeds as follows. The program reads the 
incoming SSL file at second intervals and checks whether the file 
will become larger, i.e. further entries are added or not. RW-
480 PLOTBASE does not start processing the job until the SSL 
file stops growing. 
SSL based jobs 
The SSL-folder is for jobs that are sent to RW-480 PLOTBASE by 
RW-480 CLIENTs or other own applications, which produce SSL 
files. The following work steps are carried out when an "SSL job" 
is received: 
1.  A subdirectory for the new job will be created automatically 
where you copy the drawing files. The name consists of the 
job file name and a internal number. 
2.  As soon as RW-480 PLOTBASE registers the job in the SSL-
folder folder, it reads the incoming SSL file at regular steps 
until it identifies it as having been completely written. If this 
SSL file does not contain all the necessary properties, the 
 
RW-480 PLOTBASE    213