Electrovoice p1200rl Betriebsanweisung

Seite von 40
32
SPECIFICATIONS /  TECHNISCHE DATEN   
P900RT
P1200RT
100V
70V
100V
70V
Rated Load Impedance
28.5Ω
14Ω
20Ω
9.8Ω
Maximum Midband Output Power
THD = 1%, 1kHz
410W
400W
590W
580W
Maximum Midband Output Voltage
THD = 1%, 1kHz, RMS, rated load
108V
74.8V
109.5V
75.4V
Rated Output Power 
THD < 0.2%, 20Hz ... 20kHz
350W
350W
500W
500W
Rated Output Voltage
THD < 0.2%, 20Hz ... 20kHz
100V
70V
100V
70V
Maximum RMS Voltage Swing
THD = 1%, 1kHz, no load
125V
87V
121V
88V
THD at rated output power, 
MBW = 80kHz, 1kHz
< 0.05%
IMD-SMPTE 
60Hz, 7kHz
< 0.1%
DIM30
3.15kHz, 15kHz
< 0.2%
Crosstalk Attenuation
ref. 1kHz, at rated output power
> 80dB
Frequency Response 
-3dB, ref. 1kHz
45Hz ... 22.5kHz
Damping Factor 
at 100Hz / 1kHz, 8Ω
>  300 / > 200 
Signal to Noise Ratio, Amplifi er
A-weighted
106dB
Signal to Noise Ratio, System
A-weighted
100dB
Input Sensitivity
at rated output power @ 4Ω, 1kHz
+6dBu (1.55V)
Max. Input Voltage
+21dBu (8.7V)
Input Impedance
20Hz ... 20kHz, balanced
20kΩ
CMR
@ 1kHz
80dB
Output Voltage
DSP OUT / Monitor
rated: +6dBu (1.55V)
max: +21dBu (8.7V)
Output Impedance
DSP OUT / Monitor
< 100Ω
Minimum Output Load
DSP OUT / Monitor
600Ω
Digital Signal Processing
AD & DA Conversion
24 Bit, Sigma-Delta, 128 x Oversampling, Linear Phase
Sample Rate
48kHz
Internal Wordlength
48 bit
Dynamic Range
115dB (typical)
Functions
Volume Control, Routing,
X-Over
(6, 12, 18, 24 dB/Oct Slope, Butterworth, Bessel, Linkwitz-Riley)
,
Filter
(Parametric EQ, Lo / Hi Shelving EQ, LPN, Lo / Hi Pass, Allpass)
,
Compressor / Limiter, Delay
  System (amplifi er) at rated conditions, both channels driven, rated loads, unless otherwise specifi ed.