Newco moo-cafe Betriebsanweisung

Seite von 36
 
26
 
Service – Calibration and Troubleshooting 
Hot & Cold (Ambient) Water Calibration Cont’d 
 
H2O Calibration Instructions-Cont’d
Calibration routine-Hot Water
Step 3
(See hot water calibration
note on previous page)
Depress button 2 (Settings)-
Display will change to” 0:30”
Place a measuring cup (at least
32 fl oz) under the left dispensing
head (and as shown by indicator
light)
24.5
Step 4
Press button 2 again, machine will
Dispense water into measuring cup for
30 seconds-When water stops, read 
water volume (in ounces) from cup.
Toggle buttons 
1(+) & 3(-)
Until measured value is displayed.
0:30