Frigidaire fcs388whcd Installationsanweisungen

Seite von 40
1
30" DUAL FUEL SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
(Models with an Electric Oven and a Gas Cooktop)
G. Minimum Cutout Depth is increased to 24" (61 cm) with backguard.
1 1/8"
(45.7 cm)
FRONT
OF
CABINET
G
   Ref.
22 7/8"
(58.1 cm)
NOTE: Wiring diagram for these appliances are enclosed in this booklet.
INSTALLATION AND SERVICE MUST BE PERFORMED BY
A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
If the information in this manual is not followed exactly, a fire or explosion may
result causing property damage, personal injury or death.
FOR YOUR SAFETY:
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone.  Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Recycled paper
Printed in Canada
If Installing Model With
Optional Side Panels,
Cutout Area Including
Countertop Must Be At
Least 30" (76.2 cm) Wide.
C
B
A
Regulator
• Door Open
(see note)
23 ½"
(59.7 cm)
CERTIFIED
WALL
Shave Raised
Edge to Clear 30"
(76.2 cm) Wide
Cooktop Rim.
1 ½" Max.
(3.8 cm Max.)
3" Min.
(7.6 cm Min.)
From Wall
This Side
Only
30" Min.
(76.2 cm Min.)
30" Min.**
(76.2 cm Min.**)
18" Min.
(45.7 cm) Min.
24" Min.
(61 cm Min.)
Approx. 1 7/8"
(4.8 cm)
Grounded Jonction Box or Wall
Outlet Should Be Located 8"
to 17" (20.3 cm to 43.2 cm)
From Right Cabinet and 2" to
4" (5.1 cm to 10.2 cm) From
Floor.
Locate Cabinet
Doors 1" (2.5
cm) Min.
from Cutout
Opening.
*Note: 29"
(73.7 cm) Wide
Opening for
Overlapping
Cooktop and
Built-in Look.
G
H
F
30"
(76.2 cm)
Exact
13"
(33 cm)
P/N 318201650 (0006) Rev. B
English – pages 1-12
Español – páginas 13-24
Français – pages 25-36
Wiring Diagrams - pages 37-40
Do not pinch the power supply cord or the flexible gas
conduit between the range and the wall.
Do not seal the range to the side cabinets.
**NOTE: 30" (76.2 cm) minimum clearance between the
cooktop and the bottom of the cabinet when the bottom
of wood or metal cabinet is protected by not less than ¼"
(0.64 cm) flame retardant millboard covered with not less
than No. 28 MSG sheet metal, 0.015" (0.4 mm) stainless
steel, 0.024" (0.6 mm) aluminum, or 0.020" (0.5 mm)
copper.
36" (91.4 cm) minimum clearance when the cabinet is
unprotected.
• NOTE: Allow at least 19 ¼" (48.9 cm) clearance for door
depth when it is open.
A. HEIGHT
B. WIDHT
C. DEPTH
TO FRONT
OF RANGE
F. MINIMUM
CUTOUT
WIDTH
G. CUTOUT
DEPTH
H. HEIGHT OF
COUNTERTOP
35 3/8" (90 cm) -
36 3/8" (92 cm)
30"
(76.2 cm)
26 1/4"
(66.7 cm)
29"
(73.7 cm)
21 3/4"
(55.2 cm)
36" (91.4 cm) standard
35 3/8" (90 cm) min.