30" ELECTRIC DROP-IN RANGE INSTALLATION INSTRUCTIONS
If oven is used in a new branch circuit installation 
(1996 NEC), mobile home, recreational vehicle, 
or where local codes DO NOT permit grounding 
through the neutral (white) wire, the appliance 
frame MUST NOT be connected to the neutral wire 
of the 4-wire electrical system. (see figure 2):
 
1.  Disconnect the power supply.
2.  Separate the green (or bare copper) and white 
appliance cable wires.
3. In the junction box:
  connect appliance and power supply cable wires as 
shown in Figure 2.
 (If your appliance is equipped with a 
white neutral conductor.)
This appliance is manufactured with a white neutral 
power supply and a frame connected copper wire. 
The frame is grounded by connection of grounding 
lead to neutral lead at the termination of the 
conduit, if used in USA, in a new branch circuit 
installation (1996 NEC), mobile home, recreational 
vehicles, where local code do not permit grounding 
trough the neutral (white) wire or in Canada, 
disconnect the white and green lead from each 
other and use ground lead to ground unit in 
accordance with local codes, connect neutral lead 
to branch circuit-neutral conductor in usual manner 
see Figure 4. If your appliance is to be connected 
to a 3 wire grounded junction box (US only), 
where local code permit connecting the appliance-
grounding conductor to the neutral (white) see 
Figure 3.
 
NOTE TO ELECTRICIAN: The armored cable leads 
supplied with the appliance are UL-recognized for 
connection to larger gauge household wiring. The 
insulation of the leads is rated at temperatures much 
higher than temperature rating of household wiring. The 
current carrying capacity of the conductor is governed by 
the temperature rating of the insulation around the wire, 
rather than the wire gauge alone.
Where local codes permit connecting the appliance-
grounding conductor to the neutral (white) wire 
(US Only) (see figure 1): 
1.  Disconnect the power supply.
2.  In the junction box:
  connect appliance and power supply cable wires as 
shown in Figure 1.
Figure 1
3-WIRE GROUNDED JUNCTION BOX
Cable from Power Supply
Black 
Wires
Junction 
Box
Cable from appliance
Ground Wire
(Bare or Green Wire)
White Wire
(Neutral)
U.L.-Listed Conduit 
Connector (or CSA listed)
Red
Wires
White Wire
(Neutral)
Figure 2
4-WIRE GROUNDED JUNCTION BOX
Cable from Power Supply
White Wire
Junction Box
Cable from appliance
White Wire
Black 
Wires
Red
Wires
Ground Wire
Ground Wire
(Bare or Green 
Wire)
U.L.-Listed Conduit 
Connector (or CSA 
listed)
Serial Plate Location
You will find the model and serial number printed on the 
serial plate. The serial plate is located as shown.
Remember to record the serial number for future 
reference.